Specifications
SeriesCTM
Digit6
PresetSingle Preset
Width72 mm
Height72 mm
Length85 mm
Power Supply100-240 VAC
Allowable Voltage Range90 ~ 110% of power supply
Power ConsumptionIndicator & Single preset: Approx. 5 W, Dual preset : Approx. 6 W
Indicator : Approx. 9 VAC, Single & Dual preset : Approx. 10 VAC
Counting Speed1 cps
30 cps
5 kcps
0 kcps
10 kcps
Prescale Range0.001 - 99.999
Min. Input Signal Width Counter ResetReset input: Selectable 1 ms or 2 ms
Min. Input Signal Width Timer ResetINA, RESET, INHIBIT, BATCH RESET (Except for CT6-1) : Selectable 1 ms or 20 ms
InputVoltage input. No voltage input (PNP, NPN selectable)
[Voltage input] Input impedance : 5.4 kΩ, "H" level : 5 - 30 VDC, "L" level : 0-2 VDC
[No voltage input] Impedance at short-circuit - Max. 1 kΩ, Residual voltage at short-circuit : Max 2 VDC, Impedance at open-circuit : Min. l00 kΩ
One-Shot Output10 ms
100 ms
1000 ms
200 ms
2000 ms
50 ms
500 ms
5000 ms
Contact OutputSingle preset type : SPDT(1c)
Contact CapacityNC: 250 VAC 2 A at resistive load
NO: 250 VAC 3 A at resistive load
Solid State OutputSingle preset type: 2 NPN open collector
Solid-State CapacityMax. 100 mA
Max. 30 VDC
Memory Protect10 years (When using nonvolatile semiconductor memory)
External Sensor Power12 VDC ±10%, Max. 100 mA
Time Accuracy (Repeat Error)Power ON start : Max. ±0.01% ±0.05 sec.
Signal start : Max. ±0.01% +0.03 sec.
Time Accuracy (Set Error)Power ON start : Max. ±0.01% ±0.05 sec.
Signal start : Max. ±0.01% +0.03 sec.
Time Accuracy (Voltage Error)Power ON start : Max. ±0.01% ±0.05 sec.
Signal start : Max. ±0.01% +0.03 sec.
Time Accuracy (Temperature Error)Power ON start : Max. ±0.01% ±0.05 sec.
Signal start : Max. ±0.01% +0.03 sec.